Mamba-Bi-LSTM with SHAP-Guided Iterative Refinement for Multimodal ARDS Diagnosis: A Dual-System Framework
Mufeng Chen, Fuchang Luo, Jia Xie, Quansheng Ren, Roberta Hlavata, Robert Hudec, Patrik Kamencay
Abstract
Acute respiratory distress syndrome (ARDS) is associated with mortality rates up to 46% and remains challenging to diagnose early due to overlapping clinical presentations. We propose a dual-system framework for multimodal ARDS diagnosis that integrates a Mamba-Bi-LSTM primary discrimination system with a TreeSHAP-based verification system whose attribution outputs iteratively refine the primary system’s feature selection gate. The primary system processes heterogeneous clinical inputs-ventilator parameters, blood gas indices, chest imaging, and EEG signals-through a selective state-space Mamba module and bidirectional LSTM layers. The verification system applies TreeSHAP attribution to independently cross-validate primary outputs, provide clinically interpretable evidence, and supply $ℓ_{1}$-normalised attribution vectors that directly modulate the Mamba feature selection gate weights during offline refinement. A confidence-and-consistency decision mechanism governs final output, and high-confidence predictions are incorporated as curriculum-filtered signals to iteratively recalibrate both systems through a confidence-gated offline refinement protocol. Evaluated on 3742 held-out patients from MIMIC-IV (internal test) and 2594 patients from the eICU Collaborative Research Database across 208 US hospitals (external validation), the complete system achieves 92.8% accuracy and an F1 score of 0.889 after offline iterative recalibration on the internal test set, with 91.6% accuracy and F1 of 0.871 on external validation, extending early warning time from 5.2 to 9.7 h. The P/F ratio consistently ranks as the top predictive feature in alignment with the Berlin definition. Ablation experiments confirm that EEG integration independently contributes a 2.7 percentage point accuracy gain and a 1.9-h extension of the warning window (McNemar $χ2=27.0$, $p<0.001$). All performance improvements over single-modality baselines and over existing methods are statistically significant ( $p<0.001$, Bonferroni-corrected). End-to-end processing latency of 350 ms per case is compatible with real-time ICU deployment.

§ The Valyu brief
Reading the full paper and taking notes. This takes a few seconds…
§ Ask this paper
Ask a question about this paper
Valyu reads the full text and answers from what the paper actually says.
Searching the other archives…