Paraphernalia
PPubMed7 Jun 2015Cited 14×

Referencing the sulcus line of the trochlear groove and removing intraoperative parallax errors improve femoral component rotation in total knee arthroplasty

Simon Talbot, Pandelis Dimitriou, Michael Mullen, John Bartlett

Abstract

Purpose Firstly, to assess and compare the accuracy and reproducibility of the sulcus line compared to Whiteside’s line. Secondly, to assess the accuracy of intraoperative techniques for using the rotational alignment of the trochlear groove to set femoral rotation. Thirdly, to assess the reproducibility of a trochlear alignment guide which removes parallax errors that occur when projecting the sulcus line onto the surface of the femur. Finally, to measure the result of combining the geometrically accurate sulcus line and the posterior condylar axis. Methods Three surgeons measured eight rotational angles on ten cadaveric femora. This included Whiteside’s line, the sulcus line and the techniques in which they can be referenced during surgery. Results Relative to the anatomical epicondylar axis, the sulcus line (mean −2.8°, SD 2.0°, range −5.4° to 0.8°) had significantly lower variance (F = 5.16, p = 0.036) than Whiteside’s line (mean −2.0°, SD 3.7°, range −6.0° to 3.4°). The trochlear alignment guide produced the best results of the intraoperative techniques by maintaining the accuracy of the sulcus line and projecting it onto the distal cut surface of the femur without change in rotational angle. Conclusion The sulcus line is more accurate and reproducible than Whiteside’s line. Removing parallax errors during surgery improves femoral component rotation. The trochlear alignment guide produced accurate results suggesting that it may be beneficial in a clinical setting. Averaging the sulcus line and posterior condylar axis on the cut surface of the femur improved accuracy over the individual landmarks. Femoral component malrotation is a common cause of patient dissatisfaction and revision surgery. By isolating the rotational alignment of the trochlear groove using the sulcus line, and maintaining its accuracy with an intraoperative guide, we can decrease the risk of femoral component malrotation and improve patient outcomes.

A figure from Referencing the sulcus line of the trochlear groove and removing intraoperative parallax errors improve femoral component rotation in total knee arthroplasty
fig. from the paper

§ The Valyu brief

Reading the full paper and taking notes. This takes a few seconds…

§ Ask this paper

Ask a question about this paper

Valyu reads the full text and answers from what the paper actually says.

Q.

Searching the other archives…