14 papers · ranked by Valyu relevance
Giovanni Melle
Axion Biosystems and MultiChannel Systems actually represent the leader companies in the production of MEAs for in vitro high-throughput applications (Figure 13Figure 13). These platforms consists of high-throughput configurations with 12 to 96 wells. Each well may have 12 or more low noise microelectrodes with few…
Scott Greenhorn, Véronique Coizet, Victor Dupuit, Bruno Fernandez + 6 more
single units recording within subcortical layers Authors: ['Scott Greenhorn' 'Véronique Coizet' 'Victor Dupuit' 'Bruno Fernandez' 'Guillaume A. Brès' 'A. Claudel' 'Pierre Gasner' 'Jan Warnking' 'Emmanuel Barbier' 'Cécile Delacour'] Abstract. Current techniques of neuroimaging, including electrical devices, are either…
Giulia Bruno
| | Contents 3 | | --- | --- | | Summary | 5 | | 1 | Cell signalling and electrophysiology development 8 | | 1.1 | Basics of cell communication and its main components 8 | | 1.1.1 | Action potential 8 | | 1.1.2 | Neuron 9 | | 1.1.3 | Cardiomyocyte 11 | | 1.2 | History of electrophysiology and MEA development 11 | | 2 |…
Yuya Sato, Hideaki Yamamoto, Hideyuki Kato, Takashi Tanii + 2 more
'Shigeo Sato' 'Ayumi Hirano‐Iwata'] 1 Research Institute of Electrical Communication, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577, Japan 2 Graduate School of Biomedical Engineering, Tohoku University, 6-6 Aramaki-aza Aoba, Aobaku, Sendai 980-8579, Japan 3 Faculty of Science and Technology, Oita…
Amritha Janardanan, Soner Sonmezoglu, Stefano Sonedda, Tom J. Zajdel + 5 more
Bacteria sense a diverse range of environmental analytes with high sensitivity and temporal resolution. Engineering and synthetic biology approaches enabled harnessing this capability through development of whole-cell biosensors that respond to specific molecules of interest. However, converting these responses into…
Andrew Cochran, Harshvardhan Gupta, Vishal Jain, Maysamreza Chamanzar + 1 more
We introduce a novel electro-optomechanic neural sensor for realizing ultra-compact neural recording probes that can detect and relay electrophysiology signals from within neural tissue. This technology addresses outstanding challenges faced by existing neural recording technologies, including the resolution trade-off…
Aminolah Hasanvand, Ali Khaleghi, Cyril Beguet, Paul Wanda + 1 more
Implantable wireless brain-machine interfaces (BMI) encounter significant challenges in miniaturization, power consumption, and high data volume. While systems utilizing high resolution microelectrode arrays offer precision brain readout and/or stimulation, achieving high-rate wireless connectivity (32-128 Mbps)…
Muhammad Saif-ur-Rehman, Omair Ali, Christian Klaes, Ioannis Iossifidis
'Ioannis Iossifidis'] Objective. Invasive brain-computer interface (BCI) research is progressing towards the realization of the motor skills rehabilitation of severely disabled patients in the real world. The size of invasively implanted microelectrode arrays and the selection of an efficient online spike sorting…
Akwasi Akwaboah, Ralph Etienne‐Cummings
Characterization of Neural MEAs Authors: ['Akwasi Akwaboah' 'Ralph Etienne‐Cummings'] Abstract—The promise of increasing channel counts in high density (> 104 ) neural Microelectrode Arrays (MEAs) for high resolution recording comes with the curse of developing faster characterization strategies for concurrent…
Yağmur Ceren Alataş, Uzay Tefek, Berk Küçükoğlu, Naz Bardakci + 2 more
'Sayedus Salehin' 'M. Selim Hanay'] electric field which causes the responsivity of the sensor to depend on the vertical position of a microparticle in the microfluidic channel. To overcome this problem, we fabricated three-dimensional (3D) electrodes at the coplanar sensing region of an underlying microwave resonator.…
Irandoost, Alireza, Bahramani, Amirreza + 8 more
This study introduces a novel, flexible, and implantable neural probe using a cost-effective microfabrication process based on a thin polyimide film. Polyimide film, known as Kapton, serves as a flexible substrate for microelectrodes, conductive tracks, and contact pads of the probe, which are made from a thin film of…
Zabir Ahmed, Xiang Li, Kanika Sarna, Harshvardhan Gupta + 2 more
Large-scale neural recording with high spatio-temporal resolution is essential for understanding information processing in brain, yet current neural interfaces fall far short of comprehensively capturing brain activity due to extremely high neuronal density and limited scalability. Although recent advances have…
Zhu Zhang, Sanli Faez
Optical methods for monitoring the electrochemical reaction at the interface are advantageous because of their table-top setup and ease of integration into reactors. Here we apply EDL-modulation microscopy to one of the main components of amperometric measurement devices: a microelectrode. We present experimental…
Yusuke Sugahara, Shigeyasu Uno
An analytic equation for electrochemical impedance of a single-cell measured with a microelectrode is presented. A previously reported equation had a practical problem that it is valid only when the microelectrode resides at the center of the cell under test. In this work, we propose a new analytic equation…